- DIY Supplies: ELECTRICAL
- Brand Name: LanYuXuan
- Origin: Mainland China
- Certification: CE
- Type: Clinical Examination Aids
- Brand Name: JNR cardiovascular diseases analyzer
- Model Number: ZXG-F
- Place of Origin: Anhui, China
- Instrument classification: Class I
clinical analytical Instruments cardiovascular diseases analyser with manufacturer price
it can test 35 items of parameters and there are 4 main items :
Vessel Status,Cardiac Function,Blood Condition and Microcirculation Function
Test parameter list
Parameter Abbr. |
Parameter |
Standard Range |
Unit |
Cardiac Function |
|||
PR |
pulse rate |
(50-100) |
(times/min) |
SV |
stroke volume |
(reference to formula) |
(ml/stroke) |
CO |
cardiac output |
(6-8) |
(L/min) |
SI |
stroke index |
(50-60) |
(ml/stroke/m2) |
CI |
cardiac index |
(3-6) |
(L/min/m2) |
VPE |
ventricular pumping effectiveness |
(reference to formula) |
(kg/stroke) |
EWK |
energy work coefficient |
(0.28-0.30) |
(mg/m2) |
HOI |
heart oxygen consumption index |
(15-26) |
(mg/m2) |
HOV |
heart oxygen consumption volume |
(24-42) |
(mg) |
LVWI |
left ventricular work index |
(40-78) |
(g/m) |
CMBR |
cardiac muscle blood rate |
(>=1) |
|
CMBV |
cardiac muscle blood volume |
(250-400) |
(ml) |
CMBN |
cardiac muscle blood need |
(250-400) |
(ml) |
SVr |
stroke volume increase of external counterpulsation |
(ml/stroke) |
|
RSVr |
stroke volume increase rate of external counterpulsation |
(>0.3) |
|
Vessel Status |
|||
PP |
pulse press |
(30-50) |
(mmHg) |
MSP |
mean systolic pressure |
(85-120) |
(mmHg) |
MDP |
mean diastolic pressure |
(65-95) |
(mmHg) |
MAP |
mean arterial pressure |
(70-100) |
(mmHg) |
AC |
arterial compliance |
(>1.2) |
(dyne·s·cm-5) |
CCP |
coronary perfusion pressure |
(60-70) |
(mmHg) |
BLK |
aorta blood leave coefficient |
(0.22-0.26) |
|
FEK |
artery flexible expand coefficient |
(0.25-0.55) |
|
TPR |
total peripheral resistance |
(800-1300) |
(dyne·s·cm-5) |
SPR |
standard peripheral resistance |
(1000-1400) |
(dyne·s·cm-5) |
VER |
ventricular ejection resistance |
(160-220) |
(dyne·s·cm-5) |
PAWP |
pulmonary arterial wedge pressure |
(6–12) |
mmHg |
PAR |
pulmonary arterial resistance |
(100-200) |
(dyne·s·cm-5) |
PAP |
pulmonary arterial pressure |
(15-20) |
(mmHg) |
Blood Condition |
|||
BV |
effective blood volume |
(reference to formula) |
(L) |
N |
blood viscosity |
(3-4) |
(cps) |
Nr |
reduced blood viscosity |
(3-4) |
(cps) |
Microcirculation Function |
|||
MHR |
half renewable rate of microcirculation |
(0.04-0.07) |
|
MRT |
half renewable time of microcirculation |
(11-19) |
(s) |
MST |
mean stagnation time of microcirculation |
(16-28) |
(s) |
:
Reviews