Digital 12 Channel 12 Lead Electrocardiograph ECG EKG Machine Interpretation PC Software

Digital 12 Channel 12 Lead Electrocardiograph ECG EKG Machine Interpretation PC Software

$889.51

Add to Wishlist
Add to Wishlist
SKU: CJZN1707167 Category:
Guaranteed Safe Checkout

Introduction

ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval that convenient to observe abnormal heart rhythm, case database management, button operation and touch screen function, etc.

Function

1)Sync collection for 12-lead ECG, a sampling accuracy of 24-bit can get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.

2)3/6/12-lead ECG waveform and other information such as print mode, sensitivity, paper speed, filter can be displayed in one screen, convenient for contrastive diagnosis.

3)Multiply printing modes and formats, including auto 12×1, auto 6×2+1 (rhythm lead), auto 6×2, auto 3×4+2 (rhythm lead), rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.

4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.

5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc., which reduces the doctor’s burden.

6)Built-in large capacity memory, convenient for case review and statistic.

7)Multi-language(Chinese, English, Turkish, Portuguese, German, Russian, Kazakh and other languages) interface and report.

8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, which meets the requirements of visiting a patient at home and body examination.

Performance

Input mode: floating and defibrillation protection

Frequency response:

Rated input amplitude Input frequency and waveform Relative output response

1.0 0.67Hz~40Hz, Sine wave ±10%a

0.5 40Hz~100Hz, Sine wave +10 %, -30 %a

0.25 100Hz~150Hz, Sine wave +10 %, -30 %a

0.5 150 Hz ~ 500 Hz, Sine wave +10 %, -100 %a

1.5 ≤1Hz,200ms, Triangle wave +0 %, -10 %b

a relative to 10Hz b relative to 200 ms

Time constant:≥ 3.2s

CMRR: >105dB

Filter: power frequency(AC50/60 Hz), EMG(25 Hz/35 Hz (-3 dB)), baseline drift filter

Recording way: thermal printing system

Specification of recording paper: 210 mm(W)×20 m(L) high-speed thermal paper

Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%

Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV

Recording mode: auto mode, rhythm mode and manual mode

Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)

Safety classification: Class I, type CF defibrillation-proof applied part

Polarization resistance voltage: ±610mV

Noise level: ≤12 µVp-p

ECG signal input sampling frequency: 32 kHz

Waveform data processing sampling frequency: 1 kHz

Sampling accuracy: 24-bit

The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected

Pacing detection channel: standard II

Accuracy of input signal: ±5%

Amplitude quantization: ≤5µV/LSB

Interchannel time deviation: <100 µs

Power supply:

AC: 100V~240V(50/60Hz)

DC: 14.8V/3500mAh rechargeable lithium battery

Degree of protection against ingress of liquid: IPX0

Working mode: continuous working

Accessories

Standard configuration:

A lead cable

A limb electrode

A chest electrode

A thermal recording paper

A power cord

An earth wire

A user manual

Physical characteristic

Working environment

Temperature: 5℃~40℃

Relative humidity: 25%~95%(non-condensing)

Atmospheric pressure: 700 hPa~1060 hPa

Transport and storage environment

Temperature: -20 ℃~+55 ℃

Relative humidity: ≤95%

Atmospheric pressure: 500 hPa~1060 hPa

Dimension: 340mm(L) × 320mm(W) × 85mm(H)

Net weight: 3.2Kg

Certification

SFDA, CMC, CE, FDA.

Weight 5.50 kg
Dimensions 431 × 384 × 240 cm
Model

ECG1200G

Reviews

There are no reviews yet.

Be the first to review “Digital 12 Channel 12 Lead Electrocardiograph ECG EKG Machine Interpretation PC Software”
Review now to get coupon!

Your email address will not be published. Required fields are marked *

Digital 12 Channel 12 Lead Electrocardiograph ECG EKG Machine Interpretation PC Software
Scroll to Top
0