- Communication method: Other
- Brand Name: DIXSG
- Origin: Mainland China
- Brand Name: SONKA
- Model Number: SK-T8X
- Place of Origin: Guangdong, China
- Instrument classification: Class II
- Warranty: 1 Year
- After-sale Service: Online technical support
- Product name: telemedicine devices
- Usage: Hospital
- Keyword: Healthcare
- Application: Medical Healthcare
- Function: Detecting Body Health
- Keywords: Multiparameter Patient Monitor
- Name: Video Audio System Conference
- Suitable for: ward management
- Size: 121*190*140CM
- Weight: 220KG
My friend, welcome to our store, if you need other models of this product, please contact me, I will send the product link for you to buy!
Whatsapp+8619330216441
Medical Hospital Health Testing Self Service Kiosk Health Booth Telemedicine Kit Devices Wifi Telemedicine
Related products
Products Description
Model No.
|
SK-T8X
|
||
Level
|
Class I, type B
|
||
Height
|
Height sensor
|
Ultrasound probe(Buy from USA)
|
|
Accuracy
|
0.01cm
|
||
Weight
|
BMI
|
Automatic calculation
|
|
Loadcell
|
500kg
|
||
Accuracy
|
±0.1kg
|
||
Body composition analysis
|
Frequencies
|
5kHz/50kHz/250kHz/500kHz
|
|
Measurement
|
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
|
||
Measurement current
|
90μA or below
|
||
Electrode material
|
Electroplating material
|
||
Measurement range
|
75.0~1,500.00Ω(0.1Ω unit)
|
||
Measurement location
|
Trunk, 4 limbs
|
||
Body temperature
|
Test Method
|
Infrared wireless hand-held temperature gun
|
|
Accurate to
|
0.1 ℃
|
||
Operation & storage temperature
|
10~40℃, 0~50℃
|
||
Operation & storage humidity
|
≤85%
|
||
Power
|
DC 9V
|
||
Dimension
|
150*75*40mm
|
||
Weight
|
180g
|
||
Human temperature range
|
32.0~42.5℃
|
||
Object temperature range
|
0~100℃
|
||
Accuracy
|
≤±0.3℃
|
||
Power consumption
|
≤120mw
|
||
Detection distance
|
5 to 8 cm
|
||
Auto-off
|
after 15 seconds
|
||
Blood pressure monitor
|
Blood pressure range
|
“(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm”
|
|
Storage capacity
|
100 pcs of record
|
||
Accuracy
|
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2%
|
||
Power
|
AC 100-240V,50-60Hz,1.6-0.8A
|
||
Operation temperature & humidity
|
5℃~40℃ 15%RH~80%RH
|
||
Transport & storage temperure & humidity
|
-20℃~55℃ <93%RH
|
||
Operation atmospheric pressure
|
80Kpa~106Kpa
|
||
Transport & storage atmospheric pressure
|
50Kpa~106Kpa
|
||
Dimension
|
471.5mm(L)*402.0mm(W)*309.0mm(H)
|
||
Electric shock protection
|
Class I, type B
|
||
Device weight
|
8kg
|
||
Arm circumference
|
17-42cm
|
||
Blood oxygen
|
Probe
|
Dual-wavelength LED
|
|
Wave length
|
Red light: 663nm, Infrared: 890nm
|
||
Range
|
35%~100%
|
||
Power of maximum light output
|
≤2mW
|
||
Blood oxygen rate accuracy
|
Range: 70%~100%, ±2%
|
||
Pulse rate accuracy
|
Range: 30~250bpm, ±2%
|
||
Operation temperature
|
5℃~40℃
|
||
Operation humidity
|
15%~95%
|
||
Atmospheric pressure
|
70kpa~106kpa
|
||
Power input
|
From main device by RS232
|
||
ECG
|
Leads
|
6 or 12 leads
|
|
Collection
|
Syhchronization
|
||
Calibration voltage
|
1mV±5%
|
||
Polarization resistance voltage
|
±300mV
|
||
Sensitivity
|
5, 10, 20(mm/mV)
|
||
Input impedance
|
≥5MΩ
|
||
Input loop current
|
<0.05uA
|
||
Heart rate range
|
20-300bmp/min
|
||
Noise level
|
≤15uVp-p
|
||
Filtering
|
EMG Filtering
|
||
Baseline filtering
|
|||
AC filtering
|
|||
Common mode rejection ratio
|
>90dB
|
||
Time constant
|
≥3.2s
|
||
Frequency response
|
0.05Hz~150Hz(-3.0dB/+0.4dB)
|
||
Rhythmic lead
|
Any leads optional
|
||
Base line adjustment
|
Automatic
|
||
Patient leak current
|
<10uA(220V-240V)
|
||
Patient auxiliary current
|
≤0.1uA(DC)
|
||
Safety standard
|
IEC II/CF
|
||
Sampling frequency
|
500Hz
|
||
Electrode
|
Chest electrodes and limb electrodes adopt international colors, each matches different color
|
||
“Blood glucose Uric acid Total cholesterol”
|
Measurement range
|
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
|
|
Measurement time
|
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S
|
||
Reference for normal
|
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L
|
||
Uric acid of male: 0.21~0.43mmol/L
|
|||
Uric acid of female: 0.16~0.36mmol/
|
|||
Uric acid of children: 0.12~0.33mmol/L
|
|||
Total cholesterol: 2.86~5.98mmol/L
|
|||
Accuracy
|
±0.3(test by standard resistance slip)
|
||
Display
|
mmol/Lx and time display
|
||
Inbuilt battery
|
3V Lithium battery
|
||
Lipid profile
|
Sample type
|
Capillary vessel whole blood sample, venous blood
|
|
Type
|
Total cholesterol
|
||
HDL: High density Lipoprotein
|
|||
TG: Triglyceride
|
|||
LDL: Low density Lipoprotein(By calculation)
|
|||
Method
|
Enzymatic colorimetric analysis
|
||
Mesurement range
|
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L)
|
||
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L)
|
|||
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L)
|
|||
Test period
|
About 120 seconds
|
||
Calibration
|
Plasma or similar product
|
||
Sample volume
|
5 microlitre
|
||
Blood glucose
|
Sample type
|
Capillary vessel whole blood sample
|
|
Measurement range
|
10-600 mg/dL(0.6-33.3mmol/L)
|
||
Sample volume
|
0.3 microlitre
|
||
Test period
|
3 seconds
|
||
Calibration
|
Plasma or similar product
|
||
HCT range
|
20-60%
|
||
RFID
|
Standard: IS0/IEC 15693
|
||
Read/write distance: 2cm
|
|||
Antenna: integrated
|
|||
Frequence: 13.56MHz
|
|||
Measurement theory for blood glucose
|
Electrochemistry, Optical spectrum
|
||
Storage capacity
|
200
|
||
Operation temperature
|
“Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)”
|
||
Operation humidity
|
10-90%
|
||
Storage temperature
|
2-30℃(36-80℉)
|
||
Display
|
LCD
|
||
Dimension
|
61*109*23(mm)
|
||
Weight
|
77.5(with battery)±1g
|
||
Battery life time
|
>1000 cycle use
|
||
Advertisement screen
|
Display screen
|
19″ LCD screen, visible under sunshine
|
|
Opertion screen
|
Display screen
|
17″ LCD screen
|
|
Dimension
|
Package dimension:
|
121(L)*190(H)*140(W)cm
|
|
Machine dimension:
|
242(H)*174(L)*61(W)cm
|
||
Inbuilt PC and processor
|
Gifa® industrial board, Intel 4 core CPU
|
||
Operation system
|
Windows 7 32bits OS
|
||
A4 printer
|
HP-P1106
|
||
Data output port
|
TCP/IP
|
||
Voltage
|
220 AC (50Hz/60Hz)
|
||
Power consumption
|
100W (Max.)
|
||
Operation and storage temperature
|
5℃~45℃(-10℃~+60℃)
|
||
Machine weight
|
76kg
|
Model No.
|
SK-T8X
|
||
Level
|
Class I, type B
|
||
Height
|
Height sensor
|
Ultrasound probe(Buy from USA)
|
|
Accuracy
|
0.01cm
|
||
Weight
|
BMI
|
Automatic calculation
|
|
Loadcell
|
500kg
|
||
Accuracy
|
±0.1kg
|
||
Body composition analysis
|
Frequencies
|
5kHz/50kHz/250kHz/500kHz
|
|
Measurement
|
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
|
||
Measurement current
|
90μA or below
|
||
Electrode material
|
Electroplating material
|
||
Measurement range
|
75.0~1,500.00Ω(0.1Ω unit)
|
||
Measurement location
|
Trunk, 4 limbs
|
||
Body temperature
|
Test Method
|
Infrared wireless hand-held temperature gun
|
|
Accurate to
|
0.1 ℃
|
||
Operation & storage temperature
|
10~40℃, 0~50℃
|
||
Operation & storage humidity
|
≤85%
|
||
Power
|
DC 9V
|
||
Dimension
|
150*75*40mm
|
||
Weight
|
180g
|
||
Human temperature range
|
32.0~42.5℃
|
||
Object temperature range
|
0~100℃
|
||
Accuracy
|
≤±0.3℃
|
||
Power consumption
|
≤120mw
|
||
Detection distance
|
5 to 8 cm
|
||
Auto-off
|
after 15 seconds
|
||
Blood pressure monitor
|
Blood pressure range
|
“(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm”
|
|
Storage capacity
|
100 pcs of record
|
||
Accuracy
|
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2%
|
||
Power
|
AC 100-240V,50-60Hz,1.6-0.8A
|
||
Operation temperature & humidity
|
5℃~40℃ 15%RH~80%RH
|
||
Transport & storage temperure & humidity
|
-20℃~55℃ <93%RH
|
||
Operation atmospheric pressure
|
80Kpa~106Kpa
|
||
Transport & storage atmospheric pressure
|
50Kpa~106Kpa
|
||
Dimension
|
471.5mm(L)*402.0mm(W)*309.0mm(H)
|
||
Electric shock protection
|
Class I, type B
|
||
Device weight
|
8kg
|
||
Arm circumference
|
17-42cm
|
||
Blood oxygen
|
Probe
|
Dual-wavelength LED
|
|
Wave length
|
Red light: 663nm, Infrared: 890nm
|
||
Range
|
35%~100%
|
||
Power of maximum light output
|
≤2mW
|
||
Blood oxygen rate accuracy
|
Range: 70%~100%, ±2%
|
||
Pulse rate accuracy
|
Range: 30~250bpm, ±2%
|
||
Operation temperature
|
5℃~40℃
|
||
Operation humidity
|
15%~95%
|
||
Atmospheric pressure
|
70kpa~106kpa
|
||
Power input
|
From main device by RS232
|
||
ECG
|
Leads
|
6 or 12 leads
|
|
Collection
|
Syhchronization
|
||
Calibration voltage
|
1mV±5%
|
||
Polarization resistance voltage
|
±300mV
|
||
Sensitivity
|
5, 10, 20(mm/mV)
|
||
Input impedance
|
≥5MΩ
|
||
Input loop current
|
<0.05uA
|
||
Heart rate range
|
20-300bmp/min
|
||
Noise level
|
≤15uVp-p
|
||
Filtering
|
EMG Filtering
|
||
Baseline filtering
|
|||
AC filtering
|
|||
Common mode rejection ratio
|
>90dB
|
||
Time constant
|
≥3.2s
|
||
Frequency response
|
0.05Hz~150Hz(-3.0dB/+0.4dB)
|
||
Rhythmic lead
|
Any leads optional
|
||
Base line adjustment
|
Automatic
|
||
Patient leak current
|
<10uA(220V-240V)
|
||
Patient auxiliary current
|
≤0.1uA(DC)
|
||
Safety standard
|
IEC II/CF
|
||
Sampling frequency
|
500Hz
|
||
Electrode
|
Chest electrodes and limb electrodes adopt international colors, each matches different color
|
||
“Blood glucose Uric acid Total cholesterol”
|
Measurement range
|
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
|
|
Measurement time
|
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S
|
||
Reference for normal
|
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L
|
||
Uric acid of male: 0.21~0.43mmol/L
|
|||
Uric acid of female: 0.16~0.36mmol/
|
|||
Uric acid of children: 0.12~0.33mmol/L
|
|||
Total cholesterol: 2.86~5.98mmol/L
|
|||
Accuracy
|
±0.3(test by standard resistance slip)
|
||
Display
|
mmol/Lx and time display
|
||
Inbuilt battery
|
3V Lithium battery
|
||
Lipid profile
|
Sample type
|
Capillary vessel whole blood sample, venous blood
|
|
Type
|
Total cholesterol
|
||
HDL: High density Lipoprotein
|
|||
TG: Triglyceride
|
|||
LDL: Low density Lipoprotein(By calculation)
|
|||
Method
|
Enzymatic colorimetric analysis
|
||
Mesurement range
|
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L)
|
||
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L)
|
|||
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L)
|
|||
Test period
|
About 120 seconds
|
||
Calibration
|
Plasma or similar product
|
||
Sample volume
|
5 microlitre
|
||
Blood glucose
|
Sample type
|
Capillary vessel whole blood sample
|
|
Measurement range
|
10-600 mg/dL(0.6-33.3mmol/L)
|
||
Sample volume
|
0.3 microlitre
|
||
Test period
|
3 seconds
|
||
Calibration
|
Plasma or similar product
|
||
HCT range
|
20-60%
|
||
RFID
|
Standard: IS0/IEC 15693
|
||
Read/write distance: 2cm
|
|||
Antenna: integrated
|
|||
Frequence: 13.56MHz
|
|||
Measurement theory for blood glucose
|
Electrochemistry, Optical spectrum
|
||
Storage capacity
|
200
|
||
Operation temperature
|
“Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)”
|
||
Operation humidity
|
10-90%
|
||
Storage temperature
|
2-30℃(36-80℉)
|
||
Display
|
LCD
|
||
Dimension
|
61*109*23(mm)
|
||
Weight
|
77.5(with battery)±1g
|
||
Battery life time
|
>1000 cycle use
|
||
Advertisement screen
|
Display screen
|
19″ LCD screen, visible under sunshine
|
|
Opertion screen
|
Display screen
|
17″ LCD screen
|
|
Dimension
|
Package dimension:
|
121(L)*190(H)*140(W)cm
|
|
Machine dimension:
|
242(H)*174(L)*61(W)cm
|
||
Inbuilt PC and processor
|
Gifa® industrial board, Intel 4 core CPU
|
||
Operation system
|
Windows 7 32bits OS
|
||
A4 printer
|
HP-P1106
|
||
Data output port
|
TCP/IP
|
||
Voltage
|
220 AC (50Hz/60Hz)
|
||
Power consumption
|
100W (Max.)
|
||
Operation and storage temperature
|
5℃~45℃(-10℃~+60℃)
|
||
Machine weight
|
76kg
|
Reviews
There are no reviews yet.