  • Communication method: Other
  • Brand Name: DIXSG
  • Origin: Mainland China
  • Brand Name: SONKA
  • Model Number: SK-T8X
  • Place of Origin: Guangdong, China
  • Instrument classification: Class II
  • Warranty: 1 Year
  • After-sale Service: Online technical support
  • Product name: telemedicine devices
  • Usage: Hospital
  • Keyword: Healthcare
  • Application: Medical Healthcare
  • Function: Detecting Body Health
  • Keywords: Multiparameter Patient Monitor
  • Name: Video Audio System Conference
  • Suitable for: ward management
  • Size: 121*190*140CM
  • Weight: 220KG
My friend, welcome to our store, if you need other models of this product, please contact me, I will send the product link for you to buy!

Whatsapp+8619330216441


Medical Hospital Health Testing Self Service Kiosk Health Booth Telemedicine Kit Devices Wifi Telemedicine

Related products

Products Description

Model No.
SK-T8X
Level
Class I, type B
Height
Height sensor
Ultrasound probe(Buy from USA)
Accuracy
0.01cm
Weight
BMI
Automatic calculation
Loadcell
500kg
Accuracy
±0.1kg
Body composition analysis
Frequencies
5kHz/50kHz/250kHz/500kHz
Measurement
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
Measurement current
90μA or below
Electrode material
Electroplating material
Measurement range
75.0~1,500.00Ω(0.1Ω unit)
Measurement location
Trunk, 4 limbs
Body temperature
Test Method
Infrared wireless hand-held temperature gun
Accurate to
0.1 ℃
Operation & storage temperature
10~40℃, 0~50℃
Operation & storage humidity
≤85%
Power
DC 9V
Dimension
150*75*40mm
Weight
180g
Human temperature range
32.0~42.5℃
Object temperature range
0~100℃
Accuracy
≤±0.3℃
Power consumption
≤120mw
Detection distance
5 to 8 cm
Auto-off
after 15 seconds
Blood pressure monitor
Blood pressure range
“(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm”
Storage capacity
100 pcs of record
Accuracy
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2%
Power
AC 100-240V,50-60Hz,1.6-0.8A
Operation temperature & humidity
5℃~40℃ 15%RH~80%RH
Transport & storage temperure & humidity
-20℃~55℃ <93%RH
Operation atmospheric pressure
80Kpa~106Kpa
Transport & storage atmospheric pressure
50Kpa~106Kpa
Dimension
471.5mm(L)*402.0mm(W)*309.0mm(H)
Electric shock protection
Class I, type B
Device weight
8kg
Arm circumference
17-42cm
Blood oxygen
Probe
Dual-wavelength LED
Wave length
Red light: 663nm, Infrared: 890nm
Range
35%~100%
Power of maximum light output
≤2mW
Blood oxygen rate accuracy
Range: 70%~100%, ±2%
Pulse rate accuracy
Range: 30~250bpm, ±2%
Operation temperature
5℃~40℃
Operation humidity
15%~95%
Atmospheric pressure
70kpa~106kpa
Power input
From main device by RS232
ECG
Leads
6 or 12 leads
Collection
Syhchronization
Calibration voltage
1mV±5%
Polarization resistance voltage
±300mV
Sensitivity
5, 10, 20(mm/mV)
Input impedance
≥5MΩ
Input loop current
<0.05uA
Heart rate range
20-300bmp/min
Noise level
≤15uVp-p
Filtering
EMG Filtering
Baseline filtering
AC filtering
Common mode rejection ratio
>90dB
Time constant
≥3.2s
Frequency response
0.05Hz~150Hz(-3.0dB/+0.4dB)
Rhythmic lead
Any leads optional
Base line adjustment
Automatic
Patient leak current
<10uA(220V-240V)
Patient auxiliary current
≤0.1uA(DC)
Safety standard
IEC II/CF
Sampling frequency
500Hz
Electrode
Chest electrodes and limb electrodes adopt international colors, each matches different color
“Blood glucose Uric acid Total cholesterol”
Measurement range
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
Measurement time
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S
Reference for normal
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L
Uric acid of male: 0.21~0.43mmol/L
Uric acid of female: 0.16~0.36mmol/
Uric acid of children: 0.12~0.33mmol/L
Total cholesterol: 2.86~5.98mmol/L
Accuracy
±0.3(test by standard resistance slip)
Display
mmol/Lx and time display
Inbuilt battery
3V Lithium battery
Lipid profile
Sample type
Capillary vessel whole blood sample, venous blood
Type
Total cholesterol
HDL: High density Lipoprotein
TG: Triglyceride
LDL: Low density Lipoprotein(By calculation)
Method
Enzymatic colorimetric analysis
Mesurement range
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L)
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L)
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L)
Test period
About 120 seconds
Calibration
Plasma or similar product
Sample volume
5 microlitre
Blood glucose
Sample type
Capillary vessel whole blood sample
Measurement range
10-600 mg/dL(0.6-33.3mmol/L)
Sample volume
0.3 microlitre
Test period
3 seconds
Calibration
Plasma or similar product
HCT range
20-60%
RFID
Standard: IS0/IEC 15693
Read/write distance: 2cm
Antenna: integrated
Frequence: 13.56MHz
Measurement theory for blood glucose
Electrochemistry, Optical spectrum
Storage capacity
200
Operation temperature
“Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)”
Operation humidity
10-90%
Storage temperature
2-30℃(36-80℉)
Display
LCD
Dimension
61*109*23(mm)
Weight
77.5(with battery)±1g
Battery life time
>1000 cycle use
Advertisement screen
Display screen
19″ LCD screen, visible under sunshine
Opertion screen
Display screen
17″ LCD screen
Dimension
Package dimension:
121(L)*190(H)*140(W)cm
Machine dimension:
242(H)*174(L)*61(W)cm
Inbuilt PC and processor
Gifa® industrial board, Intel 4 core CPU
Operation system
Windows 7 32bits OS
A4 printer
HP-P1106
Data output port
TCP/IP
Voltage
220 AC (50Hz/60Hz)
Power consumption
100W (Max.)
Operation and storage temperature
5℃~45℃(-10℃~+60℃)
Machine weight
76kg

Model No.
SK-T8X
Level
Class I, type B
Height
Height sensor
Ultrasound probe(Buy from USA)
Accuracy
0.01cm
Weight
BMI
Automatic calculation
Loadcell
500kg
Accuracy
±0.1kg
Body composition analysis
Frequencies
5kHz/50kHz/250kHz/500kHz
Measurement
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
Measurement current
90μA or below
Electrode material
Electroplating material
Measurement range
75.0~1,500.00Ω(0.1Ω unit)
Measurement location
Trunk, 4 limbs
Body temperature
Test Method
Infrared wireless hand-held temperature gun
Accurate to
0.1 ℃
Operation & storage temperature
10~40℃, 0~50℃
Operation & storage humidity
≤85%
Power
DC 9V
Dimension
150*75*40mm
Weight
180g
Human temperature range
32.0~42.5℃
Object temperature range
0~100℃
Accuracy
≤±0.3℃
Power consumption
≤120mw
Detection distance
5 to 8 cm
Auto-off
after 15 seconds
Blood pressure monitor
Blood pressure range
“(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm”
Storage capacity
100 pcs of record
Accuracy
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2%
Power
AC 100-240V,50-60Hz,1.6-0.8A
Operation temperature & humidity
5℃~40℃ 15%RH~80%RH
Transport & storage temperure & humidity
-20℃~55℃ <93%RH
Operation atmospheric pressure
80Kpa~106Kpa
Transport & storage atmospheric pressure
50Kpa~106Kpa
Dimension
471.5mm(L)*402.0mm(W)*309.0mm(H)
Electric shock protection
Class I, type B
Device weight
8kg
Arm circumference
17-42cm
Blood oxygen
Probe
Dual-wavelength LED
Wave length
Red light: 663nm, Infrared: 890nm
Range
35%~100%
Power of maximum light output
≤2mW
Blood oxygen rate accuracy
Range: 70%~100%, ±2%
Pulse rate accuracy
Range: 30~250bpm, ±2%
Operation temperature
5℃~40℃
Operation humidity
15%~95%
Atmospheric pressure
70kpa~106kpa
Power input
From main device by RS232
ECG
Leads
6 or 12 leads
Collection
Syhchronization
Calibration voltage
1mV±5%
Polarization resistance voltage
±300mV
Sensitivity
5, 10, 20(mm/mV)
Input impedance
≥5MΩ
Input loop current
<0.05uA
Heart rate range
20-300bmp/min
Noise level
≤15uVp-p
Filtering
EMG Filtering
Baseline filtering
AC filtering
Common mode rejection ratio
>90dB
Time constant
≥3.2s
Frequency response
0.05Hz~150Hz(-3.0dB/+0.4dB)
Rhythmic lead
Any leads optional
Base line adjustment
Automatic
Patient leak current
<10uA(220V-240V)
Patient auxiliary current
≤0.1uA(DC)
Safety standard
IEC II/CF
Sampling frequency
500Hz
Electrode
Chest electrodes and limb electrodes adopt international colors, each matches different color
“Blood glucose Uric acid Total cholesterol”
Measurement range
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
Measurement time
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S
Reference for normal
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L
Uric acid of male: 0.21~0.43mmol/L
Uric acid of female: 0.16~0.36mmol/
Uric acid of children: 0.12~0.33mmol/L
Total cholesterol: 2.86~5.98mmol/L
Accuracy
±0.3(test by standard resistance slip)
Display
mmol/Lx and time display
Inbuilt battery
3V Lithium battery
Lipid profile
Sample type
Capillary vessel whole blood sample, venous blood
Type
Total cholesterol
HDL: High density Lipoprotein
TG: Triglyceride
LDL: Low density Lipoprotein(By calculation)
Method
Enzymatic colorimetric analysis
Mesurement range
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L)
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L)
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L)
Test period
About 120 seconds
Calibration
Plasma or similar product
Sample volume
5 microlitre
Blood glucose
Sample type
Capillary vessel whole blood sample
Measurement range
10-600 mg/dL(0.6-33.3mmol/L)
Sample volume
0.3 microlitre
Test period
3 seconds
Calibration
Plasma or similar product
HCT range
20-60%
RFID
Standard: IS0/IEC 15693
Read/write distance: 2cm
Antenna: integrated
Frequence: 13.56MHz
Measurement theory for blood glucose
Electrochemistry, Optical spectrum
Storage capacity
200
Operation temperature
“Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)”
Operation humidity
10-90%
Storage temperature
2-30℃(36-80℉)
Display
LCD
Dimension
61*109*23(mm)
Weight
77.5(with battery)±1g
Battery life time
>1000 cycle use
Advertisement screen
Display screen
19″ LCD screen, visible under sunshine
Opertion screen
Display screen
17″ LCD screen
Dimension
Package dimension:
121(L)*190(H)*140(W)cm
Machine dimension:
242(H)*174(L)*61(W)cm
Inbuilt PC and processor
Gifa® industrial board, Intel 4 core CPU
Operation system
Windows 7 32bits OS
A4 printer
HP-P1106
Data output port
TCP/IP
Voltage
220 AC (50Hz/60Hz)
Power consumption
100W (Max.)
Operation and storage temperature
5℃~45℃(-10℃~+60℃)
Machine weight
76kg


Reviews

There are no reviews yet.

Be the first to review “Medical Hospital Health Testing Self Service Kiosk Health Booth Telemedicine Kit Devices Wifi Telemedicine”
Review now to get coupon!

Your email address will not be published. Required fields are marked *

Medical Hospital Health Testing Self Service Kiosk Health Booth Telemedicine Kit Devices Wifi Telemedicine
$35,098.11

Availability: 9 in stock

Add to Wishlist
Add to Wishlist
Scroll to Top
0