- Communication method: Other
- Brand Name: DIXSG
- Origin: Mainland China
- Brand Name: SONKA
- Model Number: SK-T8X
- Place of Origin: Guangdong, China
- Instrument classification: Class II
- Warranty: 1 Year
- After-sale Service: Online technical support
- Product name: telemedicine devices
- Usage: Hospital
- Keyword: Healthcare
- Application: Medical Healthcare
- Function: Detecting Body Health
- Keywords: Multiparameter Patient Monitor
- Name: Video Audio System Conference
- Suitable for: ward management
- Size: 121*190*140CM
- Weight: 220KG
My friend, welcome to our store, if you need other models of this product, please contact me, I will send the product link for you to buy!
 
       
     
       
     
       
     
       
     
       
     
       
     
       
     
       
     
       
     
       
     
          
        
          
        
Whatsapp+8619330216441
 
         Medical Hospital Health Testing Self Service Kiosk Health Booth Telemedicine Kit Devices Wifi Telemedicine
        
     Related products
    
     Products Description
    
 
      
      
      
      
      
      
      
      
      
      
         
        | 
          Model No.
          | 
          SK-T8X
          | ||
| 
          Level
          | 
          Class I, type B
          | ||
| 
          Height
          | 
          Height sensor
          | 
          Ultrasound probe(Buy from USA)
          | |
| 
          Accuracy
          | 
          0.01cm
          | ||
| 
          Weight
          | 
          BMI
          | 
          Automatic calculation
          | |
| 
          Loadcell
          | 
          500kg
          | ||
| 
          Accuracy
          | 
          ±0.1kg
          | ||
| 
          Body composition analysis
          | 
          Frequencies
          | 
          5kHz/50kHz/250kHz/500kHz
          | |
| 
          Measurement
          | 
          Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
          | ||
| 
          Measurement current
          | 
          90μA or below
          | ||
| 
          Electrode material
          | 
          Electroplating material
          | ||
| 
          Measurement range
          | 
          75.0~1,500.00Ω(0.1Ω unit)
          | ||
| 
          Measurement location
          | 
          Trunk, 4 limbs
          | ||
| 
          Body temperature
          | 
          Test Method
          | 
          Infrared wireless hand-held temperature gun
          | |
| 
          Accurate to
          | 
          0.1 ℃
          | ||
| 
          Operation & storage temperature
          | 
          10~40℃, 0~50℃
          | ||
| 
          Operation & storage humidity
          | 
          ≤85%
          | ||
| 
          Power
          | 
          DC 9V
          | ||
| 
          Dimension
          | 
          150*75*40mm
          | ||
| 
          Weight
          | 
          180g
          | ||
| 
          Human temperature range
          | 
          32.0~42.5℃
          | ||
| 
          Object temperature range
          | 
          0~100℃
          | ||
| 
          Accuracy
          | 
          ≤±0.3℃
          | ||
| 
          Power consumption
          | 
          ≤120mw
          | ||
| 
          Detection distance
          | 
          5 to 8 cm
          | ||
| 
          Auto-off
          | 
          after 15 seconds
          | ||
| 
          Blood pressure monitor
          | 
          Blood pressure range
          | 
          “(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm”
          | |
| 
          Storage capacity
          | 
          100 pcs of record
          | ||
| 
          Accuracy
          | 
          Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2%
          | ||
| 
          Power
          | 
          AC 100-240V,50-60Hz,1.6-0.8A
          | ||
| 
          Operation temperature & humidity
          | 
          5℃~40℃ 15%RH~80%RH
          | ||
| 
          Transport & storage temperure & humidity
          | 
          -20℃~55℃ <93%RH
          | ||
| 
          Operation atmospheric pressure
          | 
          80Kpa~106Kpa
          | ||
| 
          Transport & storage atmospheric pressure
          | 
          50Kpa~106Kpa
          | ||
| 
          Dimension
          | 
          471.5mm(L)*402.0mm(W)*309.0mm(H)
          | ||
| 
          Electric shock protection
          | 
          Class I, type B
          | ||
| 
          Device weight
          | 
          8kg
          | ||
| 
          Arm circumference
          | 
          17-42cm
          | ||
| 
          Blood oxygen
          | 
          Probe
          | 
          Dual-wavelength LED
          | |
| 
          Wave length
          | 
          Red light: 663nm, Infrared: 890nm
          | ||
| 
          Range
          | 
          35%~100%
          | ||
| 
          Power of maximum light output
          | 
          ≤2mW
          | ||
| 
          Blood oxygen rate accuracy
          | 
          Range: 70%~100%, ±2%
          | ||
| 
          Pulse rate accuracy
          | 
          Range: 30~250bpm, ±2%
          | ||
| 
          Operation temperature
          | 
          5℃~40℃
          | ||
| 
          Operation humidity
          | 
          15%~95%
          | ||
| 
          Atmospheric pressure
          | 
          70kpa~106kpa
          | ||
| 
          Power input
          | 
          From main device by RS232
          | ||
| 
          ECG
          | 
          Leads
          | 
          6 or 12 leads
          | |
| 
          Collection
          | 
          Syhchronization
          | ||
| 
          Calibration voltage
          | 
          1mV±5%
          | ||
| 
          Polarization resistance voltage
          | 
          ±300mV
          | ||
| 
          Sensitivity
          | 
          5, 10, 20(mm/mV)
          | ||
| 
          Input impedance
          | 
          ≥5MΩ
          | ||
| 
          Input loop current
          | 
          <0.05uA
          | ||
| 
          Heart rate range
          | 
          20-300bmp/min
          | ||
| 
          Noise level
          | 
          ≤15uVp-p
          | ||
| 
          Filtering
          | 
          EMG Filtering
          | ||
| 
          Baseline filtering
          | |||
| 
          AC filtering
          | |||
| 
          Common mode rejection ratio
          | 
          >90dB
          | ||
| 
          Time constant
          | 
          ≥3.2s
          | ||
| 
          Frequency response
          | 
          0.05Hz~150Hz(-3.0dB/+0.4dB)
          | ||
| 
          Rhythmic lead
          | 
          Any leads optional
          | ||
| 
          Base line adjustment
          | 
          Automatic
          | ||
| 
          Patient leak current
          | 
          <10uA(220V-240V)
          | ||
| 
          Patient auxiliary current
          | 
          ≤0.1uA(DC)
          | ||
| 
          Safety standard
          | 
          IEC II/CF
          | ||
| 
          Sampling frequency
          | 
          500Hz
          | ||
| 
          Electrode
          | 
          Chest electrodes and limb electrodes adopt international colors, each matches different color
          | ||
| 
          “Blood glucose Uric acid Total cholesterol”
          | 
          Measurement range
          | 
          Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
          | |
| 
          Measurement time
          | 
          blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S
          | ||
| 
          Reference for normal
          | 
          Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L
          | ||
| 
          Uric acid of male: 0.21~0.43mmol/L
          | |||
| 
          Uric acid of female: 0.16~0.36mmol/
          | |||
| 
          Uric acid of children: 0.12~0.33mmol/L
          | |||
| 
          Total cholesterol: 2.86~5.98mmol/L
          | |||
| 
          Accuracy
          | 
          ±0.3(test by standard resistance slip)
          | ||
| 
          Display
          | 
          mmol/Lx and time display
          | ||
| 
          Inbuilt battery
          | 
          3V Lithium battery
          | ||
| 
          Lipid profile
          | 
          Sample type
          | 
          Capillary vessel whole blood sample, venous blood
          | |
| 
          Type
          | 
          Total cholesterol
          | ||
| 
          HDL: High density Lipoprotein
          | |||
| 
          TG: Triglyceride
          | |||
| 
          LDL: Low density Lipoprotein(By calculation)
          | |||
| 
          Method
          | 
          Enzymatic colorimetric analysis
          | ||
| 
          Mesurement range
          | 
          Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L)
          | ||
| 
          Triglyceride: 70-600mg/dL(0.8-6.8mmol/L)
          | |||
| 
          High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L)
          | |||
| 
          Test period
          | 
          About 120 seconds
          | ||
| 
          Calibration
          | 
          Plasma or similar product
          | ||
| 
          Sample volume
          | 
          5 microlitre
          | ||
| 
          Blood glucose
          | 
          Sample type
          | 
          Capillary vessel whole blood sample
          | |
| 
          Measurement range
          | 
          10-600 mg/dL(0.6-33.3mmol/L)
          | ||
| 
          Sample volume
          | 
          0.3 microlitre
          | ||
| 
          Test period
          | 
          3 seconds
          | ||
| 
          Calibration
          | 
          Plasma or similar product
          | ||
| 
          HCT range
          | 
          20-60%
          | ||
| 
          RFID
          | 
          Standard: IS0/IEC 15693
          | ||
| 
          Read/write distance: 2cm
          | |||
| 
          Antenna: integrated
          | |||
| 
          Frequence: 13.56MHz
          | |||
| 
          Measurement theory for blood glucose
          | 
          Electrochemistry, Optical spectrum
          | ||
| 
          Storage capacity
          | 
          200
          | ||
| 
          Operation temperature
          | 
          “Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)”
          | ||
| 
          Operation humidity
          | 
          10-90%
          | ||
| 
          Storage temperature
          | 
          2-30℃(36-80℉)
          | ||
| 
          Display
          | 
          LCD
          | ||
| 
          Dimension
          | 
          61*109*23(mm)
          | ||
| 
          Weight
          | 
          77.5(with battery)±1g
          | ||
| 
          Battery life time
          | 
          >1000 cycle use
          | ||
| 
          Advertisement screen
          | 
          Display screen
          | 
          19″ LCD screen, visible under sunshine
          | |
| 
          Opertion screen
          | 
          Display screen
          | 
          17″ LCD screen
          | |
| 
          Dimension
          | 
          Package dimension:
          | 
          121(L)*190(H)*140(W)cm
          | |
| 
          Machine dimension:
          | 
          242(H)*174(L)*61(W)cm
          | ||
| 
          Inbuilt PC and processor
          | 
          Gifa® industrial board, Intel 4 core CPU
          | ||
| 
          Operation system
          | 
          Windows 7 32bits OS
          | ||
| 
          A4 printer
          | 
          HP-P1106
          | ||
| 
          Data output port
          | 
          TCP/IP
          | ||
| 
          Voltage
          | 
          220 AC (50Hz/60Hz)
          | ||
| 
          Power consumption
          | 
          100W (Max.)
          | ||
| 
          Operation and storage temperature
          | 
          5℃~45℃(-10℃~+60℃)
          | ||
| 
          Machine weight
          | 
          76kg
          | ||
| 
          Model No.
          | 
          SK-T8X
          | ||
| 
          Level
          | 
          Class I, type B
          | ||
| 
          Height
          | 
          Height sensor
          | 
          Ultrasound probe(Buy from USA)
          | |
| 
          Accuracy
          | 
          0.01cm
          | ||
| 
          Weight
          | 
          BMI
          | 
          Automatic calculation
          | |
| 
          Loadcell
          | 
          500kg
          | ||
| 
          Accuracy
          | 
          ±0.1kg
          | ||
| 
          Body composition analysis
          | 
          Frequencies
          | 
          5kHz/50kHz/250kHz/500kHz
          | |
| 
          Measurement
          | 
          Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
          | ||
| 
          Measurement current
          | 
          90μA or below
          | ||
| 
          Electrode material
          | 
          Electroplating material
          | ||
| 
          Measurement range
          | 
          75.0~1,500.00Ω(0.1Ω unit)
          | ||
| 
          Measurement location
          | 
          Trunk, 4 limbs
          | ||
| 
          Body temperature
          | 
          Test Method
          | 
          Infrared wireless hand-held temperature gun
          | |
| 
          Accurate to
          | 
          0.1 ℃
          | ||
| 
          Operation & storage temperature
          | 
          10~40℃, 0~50℃
          | ||
| 
          Operation & storage humidity
          | 
          ≤85%
          | ||
| 
          Power
          | 
          DC 9V
          | ||
| 
          Dimension
          | 
          150*75*40mm
          | ||
| 
          Weight
          | 
          180g
          | ||
| 
          Human temperature range
          | 
          32.0~42.5℃
          | ||
| 
          Object temperature range
          | 
          0~100℃
          | ||
| 
          Accuracy
          | 
          ≤±0.3℃
          | ||
| 
          Power consumption
          | 
          ≤120mw
          | ||
| 
          Detection distance
          | 
          5 to 8 cm
          | ||
| 
          Auto-off
          | 
          after 15 seconds
          | ||
| 
          Blood pressure monitor
          | 
          Blood pressure range
          | 
          “(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm”
          | |
| 
          Storage capacity
          | 
          100 pcs of record
          | ||
| 
          Accuracy
          | 
          Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2%
          | ||
| 
          Power
          | 
          AC 100-240V,50-60Hz,1.6-0.8A
          | ||
| 
          Operation temperature & humidity
          | 
          5℃~40℃ 15%RH~80%RH
          | ||
| 
          Transport & storage temperure & humidity
          | 
          -20℃~55℃ <93%RH
          | ||
| 
          Operation atmospheric pressure
          | 
          80Kpa~106Kpa
          | ||
| 
          Transport & storage atmospheric pressure
          | 
          50Kpa~106Kpa
          | ||
| 
          Dimension
          | 
          471.5mm(L)*402.0mm(W)*309.0mm(H)
          | ||
| 
          Electric shock protection
          | 
          Class I, type B
          | ||
| 
          Device weight
          | 
          8kg
          | ||
| 
          Arm circumference
          | 
          17-42cm
          | ||
| 
          Blood oxygen
          | 
          Probe
          | 
          Dual-wavelength LED
          | |
| 
          Wave length
          | 
          Red light: 663nm, Infrared: 890nm
          | ||
| 
          Range
          | 
          35%~100%
          | ||
| 
          Power of maximum light output
          | 
          ≤2mW
          | ||
| 
          Blood oxygen rate accuracy
          | 
          Range: 70%~100%, ±2%
          | ||
| 
          Pulse rate accuracy
          | 
          Range: 30~250bpm, ±2%
          | ||
| 
          Operation temperature
          | 
          5℃~40℃
          | ||
| 
          Operation humidity
          | 
          15%~95%
          | ||
| 
          Atmospheric pressure
          | 
          70kpa~106kpa
          | ||
| 
          Power input
          | 
          From main device by RS232
          | ||
| 
          ECG
          | 
          Leads
          | 
          6 or 12 leads
          | |
| 
          Collection
          | 
          Syhchronization
          | ||
| 
          Calibration voltage
          | 
          1mV±5%
          | ||
| 
          Polarization resistance voltage
          | 
          ±300mV
          | ||
| 
          Sensitivity
          | 
          5, 10, 20(mm/mV)
          | ||
| 
          Input impedance
          | 
          ≥5MΩ
          | ||
| 
          Input loop current
          | 
          <0.05uA
          | ||
| 
          Heart rate range
          | 
          20-300bmp/min
          | ||
| 
          Noise level
          | 
          ≤15uVp-p
          | ||
| 
          Filtering
          | 
          EMG Filtering
          | ||
| 
          Baseline filtering
          | |||
| 
          AC filtering
          | |||
| 
          Common mode rejection ratio
          | 
          >90dB
          | ||
| 
          Time constant
          | 
          ≥3.2s
          | ||
| 
          Frequency response
          | 
          0.05Hz~150Hz(-3.0dB/+0.4dB)
          | ||
| 
          Rhythmic lead
          | 
          Any leads optional
          | ||
| 
          Base line adjustment
          | 
          Automatic
          | ||
| 
          Patient leak current
          | 
          <10uA(220V-240V)
          | ||
| 
          Patient auxiliary current
          | 
          ≤0.1uA(DC)
          | ||
| 
          Safety standard
          | 
          IEC II/CF
          | ||
| 
          Sampling frequency
          | 
          500Hz
          | ||
| 
          Electrode
          | 
          Chest electrodes and limb electrodes adopt international colors, each matches different color
          | ||
| 
          “Blood glucose Uric acid Total cholesterol”
          | 
          Measurement range
          | 
          Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
          | |
| 
          Measurement time
          | 
          blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S
          | ||
| 
          Reference for normal
          | 
          Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L
          | ||
| 
          Uric acid of male: 0.21~0.43mmol/L
          | |||
| 
          Uric acid of female: 0.16~0.36mmol/
          | |||
| 
          Uric acid of children: 0.12~0.33mmol/L
          | |||
| 
          Total cholesterol: 2.86~5.98mmol/L
          | |||
| 
          Accuracy
          | 
          ±0.3(test by standard resistance slip)
          | ||
| 
          Display
          | 
          mmol/Lx and time display
          | ||
| 
          Inbuilt battery
          | 
          3V Lithium battery
          | ||
| 
          Lipid profile
          | 
          Sample type
          | 
          Capillary vessel whole blood sample, venous blood
          | |
| 
          Type
          | 
          Total cholesterol
          | ||
| 
          HDL: High density Lipoprotein
          | |||
| 
          TG: Triglyceride
          | |||
| 
          LDL: Low density Lipoprotein(By calculation)
          | |||
| 
          Method
          | 
          Enzymatic colorimetric analysis
          | ||
| 
          Mesurement range
          | 
          Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L)
          | ||
| 
          Triglyceride: 70-600mg/dL(0.8-6.8mmol/L)
          | |||
| 
          High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L)
          | |||
| 
          Test period
          | 
          About 120 seconds
          | ||
| 
          Calibration
          | 
          Plasma or similar product
          | ||
| 
          Sample volume
          | 
          5 microlitre
          | ||
| 
          Blood glucose
          | 
          Sample type
          | 
          Capillary vessel whole blood sample
          | |
| 
          Measurement range
          | 
          10-600 mg/dL(0.6-33.3mmol/L)
          | ||
| 
          Sample volume
          | 
          0.3 microlitre
          | ||
| 
          Test period
          | 
          3 seconds
          | ||
| 
          Calibration
          | 
          Plasma or similar product
          | ||
| 
          HCT range
          | 
          20-60%
          | ||
| 
          RFID
          | 
          Standard: IS0/IEC 15693
          | ||
| 
          Read/write distance: 2cm
          | |||
| 
          Antenna: integrated
          | |||
| 
          Frequence: 13.56MHz
          | |||
| 
          Measurement theory for blood glucose
          | 
          Electrochemistry, Optical spectrum
          | ||
| 
          Storage capacity
          | 
          200
          | ||
| 
          Operation temperature
          | 
          “Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)”
          | ||
| 
          Operation humidity
          | 
          10-90%
          | ||
| 
          Storage temperature
          | 
          2-30℃(36-80℉)
          | ||
| 
          Display
          | 
          LCD
          | ||
| 
          Dimension
          | 
          61*109*23(mm)
          | ||
| 
          Weight
          | 
          77.5(with battery)±1g
          | ||
| 
          Battery life time
          | 
          >1000 cycle use
          | ||
| 
          Advertisement screen
          | 
          Display screen
          | 
          19″ LCD screen, visible under sunshine
          | |
| 
          Opertion screen
          | 
          Display screen
          | 
          17″ LCD screen
          | |
| 
          Dimension
          | 
          Package dimension:
          | 
          121(L)*190(H)*140(W)cm
          | |
| 
          Machine dimension:
          | 
          242(H)*174(L)*61(W)cm
          | ||
| 
          Inbuilt PC and processor
          | 
          Gifa® industrial board, Intel 4 core CPU
          | ||
| 
          Operation system
          | 
          Windows 7 32bits OS
          | ||
| 
          A4 printer
          | 
          HP-P1106
          | ||
| 
          Data output port
          | 
          TCP/IP
          | ||
| 
          Voltage
          | 
          220 AC (50Hz/60Hz)
          | ||
| 
          Power consumption
          | 
          100W (Max.)
          | ||
| 
          Operation and storage temperature
          | 
          5℃~45℃(-10℃~+60℃)
          | ||
| 
          Machine weight
          | 
          76kg
          | ||
 
 
															





 











 
															





Reviews
There are no reviews yet.