- Origin: China
- Model Number: ECG300G
- Item Type: Electrocardioscanner
- Material: ABS
- Brand Name: Contec
- Certification: CE






Introduction
ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
Performance
- 
Input mode: floating and defibrillation protection 
- 
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB) 
- 
CMRR: >60dB, >100dB(add filter) 
- 
Time constant:≥ 3.2s 
- 
Patient leak current: <10µA 
- 
Calibration voltage: 1mV 
- 
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% 
- 
Noise level: <15µVp-p 
- 
Input circuit current: ≤50nA 
- 
Input impedance: ≥50MΩ 
- 
Sampling accuracy: 12-bit 
- 
Safety classification: class I, type CF and defibrillation-proof applied part 
- 
Recording mode: thermal printing system 
- 
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing. 
- 
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing. 
- 
Manual record: set record according to record format, manually switching leads. 
- 
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) 
- 
Paper size: 80mm(W)×20m(L) 
- 
Sampling frequency: 1000Hz 
- 
EMG interference filter: 25Hz/35Hz (-3dB) 
- 
Power frequency filter: AC 50Hz/60Hz(-20dB) 
- 
Paper speed: 
- 
Auto: 25, 50mm/s, ±5% 
- 
Rhythm: 25, 50mm/s, ±5% 
- 
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5% 
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
ECG-Sync software
Physical characteristic
- 
Power supply: 
- 
AC: 100V~240V(50/60Hz) 
- 
DC: 7.4V/3500mAh rechargeable lithium battery 
- 
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V 
- 
Waterproof degree: IPX0 
- 
Working mode: continuous working 


 
															



 



 
															